摘要

Based on the least square method and error estimation theory, the planar positioning error of 5-station TDOA positioning system with a redundant measuring station was studied by numerical computation method in three-dimensional space. Result obtained is different from that based on probability positioning algorithm. The comparison compared with the 4-station TOA positioning system indicates that the measuring error of variable nearly parallel to coordinate axis can be significantly reduced by increasing the quantity of measuring station providing that the target moves alone straight line in horizontal.
机译:基于最小二乘法和误差估计理论,通过三维空间中的数值计算方法研究了用冗余测量站的5站TDOA定位系统的平面定位误差。得到的结果与基于概率定位算法的结果不同。与4站TOA定位系统相比的比较表明,通过增加测量站的数量,可以显着降低与坐标轴的变量几乎平行的测量误差,从而使目标在水平中单独移动直线。