首页> 外文会议>Power Plant Air pollutant Control "MEGA" Symposium >Emission of Polycyclic Aromatic Hydrocarbons Associated with Particulate Matter from a Coal-Fired Power Plant in Vietnam
【24h】

Emission of Polycyclic Aromatic Hydrocarbons Associated with Particulate Matter from a Coal-Fired Power Plant in Vietnam

机译:与越南燃煤发电厂的颗粒物质相关的多环芳烃排放

获取原文

摘要

Integrated samples of particulate matter have been taken iso-kinetically from the flue gas of Bai Bang thermal coal-fired power plant using glass fibre filters. The samples have been Soxhlet extracted with CH_2Cl_2 and analysed by high performance liquid chromatography with fluorescence detection (HPLC/FLD) and/or gas chromatography with mass spectrometer detection (GC/MS). Anthracene, benzo[a]anthacene, phenanthrene, fluoranthene, pyrene, chrysene and benzo[a]pyrene, have been all present on the particulate matter, and the quantification of the latter five have yielded concentrations of 12.1, 6.3, 4.8, 3.0, 0.20 ng/m~3 at normal conditions, emission factors of 111, 57, 43, 27, 2 ng/kg coal, and emission rates of 2207, 1122, 847, 535, 38μg/h, respectively. The obtained concentrations, emission factors, as well as recoveries have been reduced with increased molecular weight of individual PAHs compounds.
机译:使用玻璃纤维过滤器从白隆热燃煤发电厂的烟气中取出颗粒物质的集成样品。用CH_2Cl_2萃取样品,并通过高效液相色谱法分析,具有荧光检测(HPLC / FLD)和/或具有质谱仪检测(GC / MS)的气相色谱分析。蒽,苯并[a]苯胺,菲丙烯,氟,芘,克莱森和苯并[a]芘全部存在于颗粒物质上,并且后两五的定量浓度为12.1,6.3,4.8,3.0,正常条件下0.20ng / m〜3,分别为111,57,43,27,2 ng / kg煤的排放因子和2207,1122,847,535,38μg/ h的排放率。通过增加单独的PAHS化合物的分子量,降低了所得浓度,排放因子以及回收率。