A centrifugal model test was performed to investigate the behavior of a geogrid-reinforced embankment on soft subsoil. The prototype was a reinforced embankment with four-lane driveways using lime-stabilized soil as backfill, which was 4-meter high, 26-meter wide, and over 20-meter thick soft silty clay. The slope angle of this embankment was 1.5(H): 1.0(V). One plastic window screen by removing 2/3 of its strings was used to simulate the prototype geogrid while sand drains with 5-mm diameter were used to simulate prototype prefabricated vertical drains.Displacements, soil pressures, and pore water pressures were measured during the test. Test results showed: (1) the settlement estimated from the markers installed on the front face of the foundation was approximately 90% of that measured by displacement sensors; (2) the elastic displacement of the subsoil was approximately 11% of the total displacement; (3) the total settlement in the prototype embankment was 1.7 m and 300-mm wide cracks occurred at the central portion of the embankment.
机译:进行离心模型试验以研究柔软底土的地理钢筋膨胀路堤的行为。原型是一种具有四车道车道的钢筋堤,采用石灰稳定的土壤作为回填,为4米高,宽26米,厚度为20米厚的软粉块。该路堤的斜角为1.5(h):1.0(v)。通过移除其2/3的弦圈进行一个塑料窗口屏幕用于模拟原型地质格栅,而具有5毫米直径的砂漏用于模拟原型预制垂直漏斗。在测试期间测量了平移,土壤压力和孔隙水压力。测试结果表明:(1)从基础前面上安装的标记估计的沉降约为通过位移传感器测量的90%; (2)底土的弹性位移约占总位移的11%; (3)原型路堤的总沉降为1.7米,堤坝的中央部分发生了1.7米,300毫米宽裂缝。