Studies on the augmentation of mass transfer due to the presence of coaxially placed entry region coils were presented in this paper. The range of flow conditions have been covered: Reynolds numbers from 1200 to 14,000 and Schmidt number from 800 to 1300. Coils were tested within a geometrical pitch 0.015, 0.025, 0.035 m and coil length 0.065, 0.095, 0.125 m. Results have shown that coils increased augmentation up to three times compared to the empty smooth tube. Entry region coil inserts show a considerable advantage over other enhancement techniques. A model was developed in terms of flow and geometric parameters and presented.g = 3.1422e8 [Re~+_m ]-0.006092 (Φ 1)-0.17246 (Φ 2)-30448 (Φ3)3.0607.
机译:本文介绍了由于存在同轴放置的入口区线圈引起的传质增加的研究。已经覆盖了流动条件范围:雷诺数从1200到14,000和800到1300的施密度数。线圈在几何间距0.015,0.025,0.035 m和线圈长度0.065,0.095,0.125μm。结果表明,与空光滑管相比,线圈增加了3倍的增强。进入区域线圈插入件在其他增强技术上显示了相当大的优势。在流动和几何参数方面开发了一种模型,并呈现.g = 3.1422E8 [Re〜+ _M] -0.006092(φ1)-0.17246(φ2)-30448(φ3)3.0607。