Introduction. Early detection of bladder carcinoma is very important clinical problem. Diagnostic yield of white light cystoscopy with random biopsies remains poor. The use of exogenous fluorescence significantly increases the sensitivity, but specificity remains low. We analyzed diagnostic efficacy of OCT during white light cystoscopy and combined use of OCT and fluorescence cystoscopy. Materials and methods. An OCT device (1280 nm wavelength with 3 mW power, 8 Fr endoscopic probe, in-depth resolution 15 μm in tissue, lateral resolution 30 μm, acquisition time 1.5 sec for a 200x200 pixels image) was used in combination with a standard Karl Storz fluorescence cystoscope. A 3% solution of 5-ALA was instilled intravesically for 2 hours before the procedure. Initial examination was made under white light. OCT imaging and biopsy of all fluorescence zones were performed in blue light. 20 patients were studied. The study is ongoing. Results. 80 fluorescence zones (16 exophytic and 64 flat lesions) were analyzed with OCT. All exophytic zones were correctly detected by OCT and white light cystoscopy. Out of 64 flat fluorescent areas, 56 had benign histopathology readings, with 45 of them having the benign type of OCT images. Of 8 fluorescent zones with neoplastic histopathology, OCT correctly detected all 8. Based on this preliminary data, OCT could help to avoid 80% of unnecessary biopsies/resections. Conclusion. Combined use of OCT imaging and fluorescence cystoscopy can substantially improve diagnostic yield of bladder neoplasia detection.
机译:介绍。早期检测膀胱癌是非常重要的临床问题。随机活检的白光膀胱镜检查的诊断产量仍然差。外源荧光的使用显着提高了敏感性,但特异性仍然低。在白光膀胱镜检查期间分析了OCT的诊断疗效,并结合了OCT和荧光膀胱镜检查。材料和方法。 OCT器件(1280nm波长3 mW功率,8br内窥镜探针,组织中深度分辨率15μm,横向分辨率30μm,用于200x200像素图像的采集时间1.5秒)与标准的Karl Storz组合使用荧光囊镜。在程序前介于膀胱内滴注3%的5-Ala溶液。在白光下进行初步检查。所有荧光区的OCT成像和活组织检查在蓝光中进行。研究了20名患者。这项研究正在进行中。结果。用OCT分析80个荧光区(16次突变和64个扁平病变)。 OCT和白光膀胱镜检查正确检测到所有突出的区域。在64个扁平的荧光区域中,56个良性组织病理学读数,其中45个具有良性类型的OCT图像。在8个荧光区具有肿瘤组织病理学,OCT正确检测到所有8.基于此初步数据,OCT可以有助于避免80%的不必要的活组织检查/切除术。结论。联合使用OCT成像和荧光膀胱镜检查可以大大提高膀胱肿瘤检测的诊断产率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号