We deposited multilayer Nanocrystalline Diamond (NCD) thin films on Ti-6A1-4V substrates that were machined to imitate the shapes of the condyle and fossa of the temporomandibular joint (TMJ). We performed low stress wear assessment experiments on condyle/fossa pairs mounted in a custom-built mandibular movement simulator (MMS) for 5 * 10~5 loaded cycles at 1.2 Hz, which is equivalent to 4.4 years of clinical use. Analysis of wear surfaces on the control and the NCD-coated pairs indicated that no film delamination occurred on the NCD-coated condyle/fossa couple and that wear damage was extensive on the uncoated condyle/fossa pair. The high stress wear tests performed using the Ortho-POD machine at loads of 80 and 165 N showed that loss of film on the condyle specimens occurred after 3300 and 341 cycles, respectively. A subsequent evaluation of the influence of condyle curvature on wear by articulating a multilayer condyle/disk pair at a load of 50 N and 250 000 cycles at 1.2 Hz, showed that film delamination on the condyle occulted after 12500 cycles and no loss of film was observed on the disk after 250 000 cycles of articulation. Our results show that the observed lower film lifetimes on the condyles at high stresses are not related to intrinsic stresses in the film but probably due to lower film adhesion on the curved surfaces of the condyle.
机译:在加工的Ti-6A1-4V基板上沉积多层纳米晶金刚石(NCD)薄膜,以模仿颞下颌关节(TMJ)的髁和窝的形状。我们对髁舱/窝配对进行了低应力磨损评估实验,其安装在定制的下颌运动模拟器(MMS)中为1.2 Hz的5 * 10〜5个装载循环,相当于4.4岁的临床用途。对照上的磨损表面和NCD涂层对的分析表明,在NCD涂层髁/窝组织上没有发生薄膜分层,并且在未涂覆的髁/窝配件上造成磨损损坏。使用在80和165n的载荷下使用邻荚机进行的高应力磨损试验表明,在3300和341个循环后,分别在髁样标本上发生膜的损失。随后通过在1.2Hz的负荷下铰接多层髁/盘对阐明髁突曲率对磨损的影响,表明在12500次循环后髁突隐匿的胶片分层,并且不会损失薄膜在25万次闭塞后在磁盘上观察到。我们的研究结果表明,高应力下髁上的观察到的下膜寿命与膜中的内在应力无关,但可能是由于髁上的弯曲表面上的较低膜粘附。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号