This study was performed for a purpose of developing a passive sampler, which can quantify formaldehyde and acetaldehyde in indoor air by sampling for about 1 hour. The method investigated in this research is a one to measure the fluorescence of s-triazolo[3,4-a]-phthalazine and 3-methyl-s-triazolo[3,4-a]phthalazine which comes from the reaction of 1-hydrazinophthalazine and HCHO and CHsCHO by HPLC with fluorescence detector. Passive sampler packed with alkali-impregnated of 0.7 g in a porous tube made from polyethylene resin was prepared. The uptake rate of HCHO and CH3CHO were 2.55 and 3.60 ug/ppm centre dot hr each. The minimum measuring limit were 0.015 ppm and 0.028 ppm for HCHO and CHsCHO with 1 hour sampling.
机译:该研究是为了开发被动采样器的目的,通过取样约1小时来量化室内空气中的甲醛和乙醛。本研究中研究的方法是测量S-Tri唑的荧光[3,4-a] - 苯嗪和3-甲基-S-三唑[3,4-a]酞嗪的荧光,这是来自1-的反应HPLC具有荧光检测器的氢肼萘嗪和HCHO和CHSCHO。制备在由聚乙烯树脂制成的多孔管中填充有0.7g碱浸渍的被动采样器。 HCHO和CH3CO的摄取率为2.55和3.60 UG / PPM中心点HR。最低测量限度为0.015ppm和0.028ppm的Hcho和Chscho,具有1小时取样。