首页> 美国政府科技报告 >Investigation of Formaldehyde and Acetaldehyde Sampling Rate and Ozone Interference for Passive Deployment of Waters Sep-Pak XPoSure Samplers.
【24h】

Investigation of Formaldehyde and Acetaldehyde Sampling Rate and Ozone Interference for Passive Deployment of Waters Sep-Pak XPoSure Samplers.

机译:用于Waters sep-pak Xposure采样器被动部署的甲醛和乙醛取样率和臭氧干扰的研究。

获取原文

摘要

This study investigated formaldehyde and acetaldehyde passive sampling rates and ozone interference for the DNPH-based Waters Sep-Pak XPoSure sampler. Previous studies have shown that ozone interferes with active sampling by this cartridge. Our study included one laboratory and six field experiments conducted in Northern California homes. Passive sampling rates of 1.10 plus or minus 0.09 and 0.86 plus or minus 0.10 mL/min determined for formaldehyde and acetaldehyde are lower than previously reported. In a controlled laboratory experiment there were small, statistically insignificant impacts of subsequent ozone exposure on formaldehyde and acetaldehyde mass passively collected on the samplers. This sampler is inexpensive, easy to deploy and to transport by mail, and has a high sampling capacity when used passively; it is suitable for a wide-range of monitoring applications. However, the passive sampling rate remains in question given the internally consistent, but different results obtained in our study and the previous study.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号