首页> 外文会议>Distributech Conference and Exhibition >'PREMIUM OPERATING DISTRICTS' PROVIDE SUPERIOR RELIABILITY FOR INDUSTRIAL CUSTOMERS USING THE DV2010 PRIMARY VOLTAGE NETWORK
【24h】

'PREMIUM OPERATING DISTRICTS' PROVIDE SUPERIOR RELIABILITY FOR INDUSTRIAL CUSTOMERS USING THE DV2010 PRIMARY VOLTAGE NETWORK

机译:使用DV2010主电压网络为工业客户提供卓越的可靠性

获取原文

摘要

Customers equate "reliability" to electric service availability. Radial feeder electric distribution systems deliver levels of perceived reliability that are typically in the range of 99.98% available service, i.e., approximately 100 minutes of annual outage time as indicated by SAIDI. The radial distribution system can be enhanced with automation to increase reliability, but even these options result in short duration power outages. New technology in commercial and industrial processes have created an environment were some customers have a zero tolerance of any type of power interruption, where a one second outage may just as well be a one hour outage because their critical processes have tripped offline and product is lost at a significant cost. Networked power distribution systems provide an answer to the high reliability requirements of these sensitive processes. The primary distribution network that is created from traditional radial distribution feeders, uses new advancements in hardware and software technology, and high-speed communication implemented to establish a multi-source distribution network to provide superior service and reliability to the Premium Operating District, "POD". This paper will discuss the equipment, philosophy and system design that is being deployed at We-Energies using the primary distribution voltage network technology that has been developed as a cooperative R&D effort when 6 utilities across the country joined together to form the Distribution Vision 2010, LLC. We Energies is using the DV2010 design to develop a pilot project in 2004 and create a Premium Power Park within the largest existing industrial park in the state of Wisconsin. The design is being implemented over the existing distribution feeder infrastructure and promises to deliver less than one minute of qualified outages to the customers, or 99.9998% available service.
机译:客户等同于“可靠性”,以电力服务的可用性。辐射状馈电线配电系统交付通常在99.98%可用的服务的范围的感知可靠性水平,即,约100分钟的每年停电时间由SAIDI指示。径向分布系统可以与自动化被增强以提高可靠性,但即使是这些选择导致短时间停电。在商业和工业流程的新技术已经创造了一个环境,是一些客户有任何类型的电源中断,的零容忍,其中一个秒钟的中断可能只是作为不失为一个小时的停电,因为他们的关键流程已经下线跳闸和产品丢失在显著的成本。网络化的功率分配系统提供一个答案对这些敏感工艺的高可靠性的要求。是从传统的径向分布馈线创建的主分配网络,使用在硬件和软件技术,和高速通信新的进步实现建立多源分布网络提供优质的服务和可靠性的高级操作区“POD ”。本文将讨论在我们-能源利用已经发展成为一个合作R&d努力当全国各地的6个实用程序结合在一起,形成了分布2010年远景在初次分配电压网络技术正在部署的设备,理念和制度设计, LLC。我们能源使用DV2010的设计开发在2004年的试点项目,并在威斯康星州最大的现有工业园区内建立一个高级技术博物馆。该设计正在通过现有的配电线路基础设施和承诺落实到交付合格的停电不到一分钟给客户,或99.9998%可用的服务。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有