High-Speed X-Ray Assessment of the Bony Kinematics of the Cervical Spine During Frontal Impacts

机译:正面撞击期间颈椎骨脊柱的高速X射线评估

获取原文

摘要

The aim of this study was to assess the feasibility of using a high-speed x-ray system (capable of 1000 frames/sec) to evaluate the bony kinematics of postmortem human surrogate (PMHS) cervical spines at real-world speeds during frontal impact. Whole-body frontal impact sled tests were performed on two fresh PMHS specimens. Screws were inserted into the tips of the spinal processes to optimize contrast on the high-speed cine x-ray. Head, T1 and sternum accelerations, as well as shoulder, and lap belt forces were recorded. Vertebral motion was captured using a modified mobile c arm x-ray system, and an image intensifier linked to a high-speed camera (Kodak motion corder analyzer, model SR 1000C, Kodak, San Diego, CA, USA) The variable parameters for the tests were camera frame rate and sled velocity. Tests were performed with delta-V's (Dv) of approximately 15 kph (8G) and 21 kph (10G). Cine x-rays of the tests were recorded at 250, 500 and 1000 frames/sec. Motion tracking analysis of the bony elements of the cervical spine was performed. Only tests recorded a 250 frames/sec produced high enough quality images to perform motion analysis. The results show high-speed cine x-ray can be used to directly visualize the bony skeleton, for the assessment of skeletal kinematics during impact. Analysis of bony kinematics using high-speed cine x-ray reduces errors caused by extrapolating data from external surface makers. Additionally, the system also offers the potential for detecting the site at which fractures originate. It also allows visualization of the timing of fractures, and the order they occur in. Further research and testing is required to optimize the use of the system, to increase the field of view and improve image quality at the highest frame rates (> 500 frames/sec).
机译:本研究的目的是评估使用高速X射线系统(能够1000帧/秒)的可行性,以在正面影响期间在实际速度下评估蛋白质人类替代(PMHS)颈椎的骨动力学。在两个新鲜PMHS标本上进行全身正面撞击橇检查。将螺钉插入脊柱过程的尖端中,以优化高速X射线上的对比度。记录头部,T1和胸骨加速度,以及肩部和肩带力。使用修改的移动C ARM X射线系统捕获椎体运动,以及连接到高速摄像机(柯达运动CORDER分析仪,型号SR 1000C,Kodak,SANIDGO,CA,USA)的图像增强器的图像增强器的变量参数测试是相机帧速率和雪橇速度。用约15kph(8g)和21kph(10g)的Delta-V的(DV)进行测试。测试的Cine X射线以250,500和1000帧/秒记录。进行宫颈脊柱的骨元素的运动跟踪分析。只有测试记录了250帧/秒,生产足够高的质量图像以执行运动分析。结果表明,高速电影X射线可用于直接可视化骨骼骨架,用于在撞击期间评估骨骼运动学。使用高速电线X射线分析骨吸动学,可降低由外表面制造商推断数据引起的误差。另外,该系统还提供了检测裂缝起源的部位的可能性。它还允许可视化裂缝的定时,以及它们发生的顺序。需要进一步的研究和测试来优化系统的使用,以增加视野并以最高帧速率提高图像质量(> 500帧/ sec)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号