The location of the peak pressure can serve as a control parameter to adjust ignition timing and optimize engine performance. The ionization sensor, an electrical probe for combustion diagnostics, can provide information about the peak pressure location. However, the reliability of such information is rather poor. In-cylinder gas flow at the electrodes may be one reason for this. We present results from an investigation of the relationship between ionization sensor current and pressure under various gas flow conditions. The gas flow velocity in the vicinity of the electrode gap was measured by LDA. From the results one may infer how the in-cylinder gas flow affects the reliability of the prediction of pressure peak location from the ionization sensor signal. One finding is that high bulk gas flow impairs the precision of the prediction in certain configurations.
机译:峰值压力的位置可以用作控制参数,以调整点火正时并优化发动机性能。电离传感器,燃烧诊断的电探针可以提供有关峰值压力位置的信息。但是,这种信息的可靠性相当差。电极处的缸内气流可能是其中的一个原因。我们通过调查各种气体流动条件下的电离传感器电流和压力之间的关系的研究。通过LDA测量电极间隙附近的气流速度。从结果中可以推断出缸内气流如何影响来自电离传感器信号的压力峰值位置的预测的可靠性。一个发现是高散装气体流量在某些配置中损害预测的精度。