This article presents an experimental determination on mode I critical strain energy release rate (c-SERR, G_(ic). Multidirectional (MD) composite beams were subjected to the double cantilever beam (DCB) test during which the applied load and the load point displacement were registered. The maximum peak force was taken into account in calculation of the G_(ic). It was computed using three different methods. On the basis of the performed test it was found that the critical strain energy release rate depends on the specimen interface.
机译:本文提出了对模式I临界应变能释放速率的实验确定(C-SERR,G_(IC)。多向(MD)复合梁经过双悬臂梁(DCB)测试,在此期间施加的负载和负载点登记位移。在计算G_(IC)时考虑了最大峰值力。使用三种不同的方法计算。基于所进行的测试,发现临界应变能释放率取决于样品界面。