Operation method and reduction of CO{sub}2 emission of a photovoltaic·solar heat/cogeneration system

机译:光伏·太阳能热/热电联产系统的CO {SUB} 2发射的操作方法和减少

获取原文

摘要

Introduction effect of a photovoltaic solar heat/cogeneration system (PV·SC/CG system ) is influenced on the operation method of the system. In this study, reduction effect of the CO{sub}2 emission and economy of the PV·SC/CG system are calculated for different operation method of the system. The PV output and solar heat energy are determined using the weather data, the gas engine output is determined with the dynamic programing. It is found that (1) In case of the PV·SC/CG system introduced in hospital, the CO{sub}2 emission reduces by 2 point in cost min. operation, but 8 point in CO{sub}2 min. operation. (2) In case of the PV·SC/CG system introduced in hotel, the CO{sub}2 emission reduces by 8 point in cost min. operation, but 9 point in CO{sub}2 min. operation.
机译:光伏太阳能热/热电池系统(PV·SC / CG系统)的引入效果对系统的操作方法影响。在该研究中,计算了用于系统的不同操作方法的PV·SC / CG系统的CO {SUB} 2发射和经济的减少效果。使用天气数据确定PV输出和太阳能热能,通过动态编程确定燃气发动机输出。发现(1)在医院引入的PV·SC / CG系统的情况下,CO {Sub} 2发射在成本最小值中减少2点。操作,但在CO {SUB}中的8个点2分钟。手术。 (2)如果在Hotel中引入的PV·SC / CG系统的情况下,CO {Sub} 2发射在成本最小的情况下减少了8点。操作,但Co {Sub}中的9个点2分钟。手术。