首页> 外文会议>SAE International Congress and Exposition >Heat transfer performance of propylene glycol versus ethylene glycol coolant solutions in laboratory testing
【24h】

Heat transfer performance of propylene glycol versus ethylene glycol coolant solutions in laboratory testing

机译:丙二醇与乙二醇冷却剂溶液在实验室试验中的传热性能

获取原文

摘要

This paper describes the results of laboratory testing comparing the heat transfer performance of heavy duty radiators with propylene glycol and ethylene glycol based coolants. Solution of 50/50 propylene glycol/water (50/50 PG/water) and 50/50 ethylene glycol/water (50/50 EG/water) were tested in radiators of different geometries. The tests showed that the performance of 50/50 PG/water is degraded at higher flow rates to a greater degree than either 50/50 EG/water or 100% water. Specifically, it was found that in typical truck radiators the cooling performance of water drops off below 2.52 L/s (40 gpm), while that of 50/50 EG/water drops off below 3.78 L/s (60 gpm) and that of 50/50 PG/water drops off below 5.05 L/s (80 gpm). It is recommended that crossflow radiator designs be used for short, wide radiator applications to maximize the fluid flow rate in the radiator tubes.
机译:本文介绍了实验室测试的结果,比较了与丙二醇和乙二醇的丙二醇的重载辐射器的传热性能进行了比较。在不同几何形状的辐射器中测试50/50丙二醇/水(50/50pg /水)和50/50乙二醇/水(50/50/50/50/50/50/50/50/50/50/50/50/50/50/50)。测试表明,50/50pg /水的性能以比50/50的更大程度降低到比50/50 /水或100%水的程度更大。具体来说,发现在典型的卡车辐射器中,水的冷却性能下降低于2.52L / s(40gpm),而50/50(例如50/50)的水滴低于3.78L / s(60 gpm),而且50/50 pg /水下降5.05升(80 gpm)。建议使用横流散热器设计用于短,宽散热器应用,以最大化散热器管中的流体流速。