A very high sensitivity, quadrupole-based inductively coupled plasma mass spectrometer (ICP-MS) has been developed and employed to measure very low concentrations (pg/L) of various actinides in solution. The detection capabilities of the instrument are shown using a variety of sample introduction methods, including simple direct sample nebulization, higher efficiency sample nebulization, and column preconcentration. This allowed three sigma detection limits in the range from 33 to 0.07 pg/L to be achieved, using short integration times, for a number of actinides. In addition, the improved sensitivity allowed isotope ratio measurements to be undertaken with good precision, (0.05 to 0.2%) at low concentrations (0.5 to 5 μg/L), without requiring long acquisition times. The results of isotope ratio measurements on silver, lead, and NIST natural lead standard SRM981 will be reported.
机译:已经开发了非常高的灵敏度,基于基于极限的电感耦合等离子体质谱仪(ICP-MS),并采用溶液中的各种散曲线的非常低浓度(PG / L)。使用各种样品引入方法显示仪器的检测能力,包括简单的直接样品雾化,更高的效率样品雾化和柱预浓度。这允许使用短的整合时间来实现三种Sigma检测限度在33至0.07pg / L的范围内,用于许多散曲线。此外,改善的敏感性使同位素比测量以良好的精度(0.05至0.2%)在低浓度下(0.5至5μg/ L),而不需要长时间的采集时间。报道了同位素比率测量的结果,将报告银,铅和NIST天然铅标准SRM981。