摘要

The analysis presented in this paper focuses on the energetic aspects of the use of photovoltaic (PV) systems in office buildings. Energy generation from PV system has been simulated on an hourly time scale and compared with the energy demand of two office buildings located in Krakow (southern Poland). The buildings' annual load exceeded 1 GWh in both cases. The analysis dealt with estimating how much energy generated by a PV system can be utilized on-site (self-consumption) and how big the energy surpluses will be (energy generation greater than demand). Capacities of PV systems ranging from 0.1 to 1.0 MW have been considered. Also, the impact of PV generation on the residual load parameters and changes in the maximal monthly and hourly energy demand were investigated. The results show that although the building energy demand is similar (in terms of annual volume of energy consumed) the potential of PV systems to cover it is different. The 100-kW PV system can reduce the observed hourly peak energy demand by 1% in December but by over 30% in June (respectively, from 171 kWh to 169 kWh, and from 333 kWh to 255 kWh). Considering the annual patterns of the office buildings' energy demand and PV generation (both have their respective peaks in summer), the application of a PV system changes the office building energy demand pattern significantly from the perspective of the power system operator. After installing 500 kW PV in an office building consuming 1 GWh annually, the months with highest demand are no longer in summer but in winter.
机译:本文提出的分析侧重于在办公楼中使用光伏(PV)系统的能量方面。 PV系统的能量在每小时尺度上进行了模拟,并与位于克拉科夫(波兰南部)的两个办公楼的能源需求进行了比较。两种情况下,建筑物的年负荷超过1百万。分析估算PV系统产生的能量可以在现场(自我消费)和能量盈余的数量有多大(能量产生大于需求)。 PV系统的电容从0.1到1.0 MW的范围内被考虑在内。此外,研究了PV生成对残余负荷参数的影响和最大月和每小时能源需求的变化。结果表明,尽管建筑能源需求相似(在每年的能量消耗的能量方面)PV系统覆盖它的潜力是不同的。 12月份,100千瓦光伏系统可以将观察到的每小时峰值能源需求减少1%,但六月(分别为171千瓦时,从333千瓦时到255千瓦时)。考虑到办公楼的能源需求和光伏生成的年度模式(夏季都有各自的峰),PV系统的应用从电力系统操作员的角度显着改变了办公室建筑能源需求模式。在每年在耗费1 GWH的办公楼安装500 KW PV之后,最高需求的月份不再在夏天,但在冬天。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号