Tertiary treatment of municipal wastewater is necessary to reduce its scaling potential for using as makeup water of circulating cooling systems. In this study the corrosivity and the factors affecting corrosion of municipal wastewater tertiary-treated by nanofiltration membrane process were assessed by weight-loss method. The results show that concentration of salt ions such as Ca~(2+), Mg~(2+), Cl~- and (SO_4)~(2-) has a significant effect on corrosivity to carbon steel. Certain quantity of calcium and magnesium ions could inhibit the corrosion of carbon steel, however, chlorine and sulfate ions could accelerate the corrosion of carbon steel. The corrosion inhibition effect of three inhibitors (PC-604, RP-101 and poly epoxy succinate (PESA)) in tertiary-treated municipal wastewater on the carbon steel was evaluated. PC-604 had the best corrosion inhibitor effect and the lowest dosage. This research has guiding significance for using tertiary-treated municipal wastewater as makeup water of circulating cooling systems.
机译:市政污水的三级处理是必要的,以减少其潜在的结垢用于使用作为循环冷却系统的补给水。在这项研究中的腐蚀性和影响市政污水三级处理的纳滤膜处理的腐蚀因素进行失重法评估。结果表明盐离子如Ca〜(2+),镁〜(2+),氯〜的该浓度 - 和(SO_4)〜(2-)对腐蚀性碳钢一个显著效果。钙和镁离子的一定量的能抑制碳钢的腐蚀,然而,氯和硫酸根离子会加速碳钢的腐蚀。三种抑制剂(PC-604,RP-101和聚环氧琥珀酸酯(PESA))在叔处理的城市对碳钢废水的腐蚀抑制作用进行评价。 PC-604有最好的防腐剂效果和最低的剂量。这项研究使用三级处理的城市废水作为循环冷却系统的补给水的指导意义。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号