摘要

The article concerns the analysis of results of coordinate measurements of ceramic products. The measured parts were made of ZrO_2 based ceramic material and machined using the CNC machine tool Ultrasonic 20 linear. The analysis of results of measurements of ceramic workpieces concerned the comparison of corrected measured points obtained by means of different algorithms of the probe radius correction process. The first algorithm was developed based on the Lagrange interpolation method of indicated measured points. The second method was the commercial one and it is available in the Calypso software which can cooperate with a coordinate measuring machine.
机译:本文涉及陶瓷产品坐标测量结果的分析。测量的部件由ZrO_2基陶瓷材料制成,并采用CNC机床超声波20线性加工。陶瓷工件测量结果的分析涉及借助于探头半径校正处理的不同算法获得的校正测量点的比较。基于指示的测量点的拉格朗日插值方法开发了第一算法。第二种方法是商业版本,它可以在Calypso软件中使用,该软件可以与坐标测量机配合。