摘要

In a single-phase photovoltaic grid connected system, the inherent second harmonic power flow results in large size impedance network of the Z-Source PV inverter. Minimization of the impedance network is a challenging area of research. So, a detailed mathematical approach based on 2ω ripple analysis is proposed. This paper depicts the 2ω modeling of Z-source inverter to obtain reduced component ratings of the impedance network. The analysis has been extended for Trans Quasi Z network and Embedded Z network and the component ratings are compared with Z network. Simulation has been carried out in MATLAB/Simulink for single phase Z-source PV inverter with impedance network designed using 2ω ripple analysis and the results are verified.
机译:在单相光伏电网连接系统中,固有的第二谐波功率流程导致Z源PV逆变器的大尺寸阻抗网络。阻抗网络的最小化是一个具有挑战性的研究领域。因此,提出了一种基于2Ω纹波分析的详细数学方法。本文描绘了Z源逆变器的2Ω建模,以获得阻抗网络的减少分量额定值。对于TransQuasi Z网络和嵌入式Z网络已经扩展了分析,并且将分量额定值与Z网络进行比较。用于单相Z源PV逆变器的MATLAB / Simulink在MATLAB / Simulink中进行了模拟,其中使用2Ω纹波分析设计的阻抗网络,并验证了结果。