首页> 外文会议>American Filtration and Separations Society Annual Meeting >Test rig MFP Nano plus for the determination of the separation efficiency of filter media according to EN 1822-3
【24h】

Test rig MFP Nano plus for the determination of the separation efficiency of filter media according to EN 1822-3

机译:试验台MFP纳米加上,根据EN 1822-3确定过滤介质的分离效率

获取原文

摘要

The MFP Nano plus with the integrated U-SMPS system (measuring particles in the size range of 5 nm up to 1 μm) can test filter media with salt aerosols as well as with oil droplets, e.g. DEHS. By choosing the adequate solution concentration in the aerosol generator the mean generated particle size is precisely defined. Thus, the system can be matched to an optimum counting statistic for the particular MPPS range (Most Penetrating Particle Size). The polydisperse test aerosol is classified with the DEMC (Differential Electrical Mobility Classifier), so that only monodisperse particles of a particular size can get on the filter media for the determination of the efficiency. This procedure minimizes loading effects caused by the test aerosol on the filter medium at the downstream measurement. The condensation particle counter UF-CPC 50 then determines fast and reliably the appropriate particle number concentration to each particle size. The UF-CPC 50 uses a large optical measurement volume and is therefore optimized for highest counting rates in very low aerosol concentrations. This procedure minimizes loading effects caused by the test aerosol on the filter medium at the downstream measurement. The series MFP for the evaluation of the dust holding capacity, the pressure loss and the efficiency of filter media has been proven to the entire satisfaction of our customers for years. The entire spectrum in air filter media testing, starting at very low efficient open media up to ULPA qualities can be carried out with the different versions of the MFP series.
机译:MFP Nano Plus与集成的U-SMPS系统(测量尺寸范围为5nm的粒子)可以测试用盐气溶胶以及油滴的过滤介质,例如油滴。 Dehs。通过在气溶胶发生器中选择足够的溶液浓度,精确地定义了平均产生的粒度。因此,该系统可以与特定MPPS范围(最渗透粒度最透过的粒度)匹配。多分散试验气溶胶分类为DEMC(差分电动机分类器),使得仅特定尺寸的单分散颗粒可以在过滤介质上达到效率。该过程最大限度地减少了在下游测量的过滤介质上的测试气溶胶引起的负载效果。然后,冷凝粒子计数器UF-CPC 50确定快速且可靠地将适当的颗粒数浓度浓度与每个颗粒尺寸一起确定。 UF-CPC 50使用大的光学测量体积,因此优化了极低的气溶胶浓度的最高计数率。该过程最大限度地减少了在下游测量的过滤介质上的测试气溶胶引起的负载效果。该系列MFP用于评估灰尘持有能力,压力损失和过滤介质的效率已被证明多年来我们客户的整体满意度。空气过滤器介质测试中的整个频谱,从非常低效的开放式介质开始,可以使用不同版本的MFP系列进行ULPA品质。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号