Objective: To improve the accuracy of multi-tumor marker protein chip and to provide more reliable evidence for the early diagnosis of cancer.Methods: Two groups of normal sample images and tumor sample images are selected randomly from the photos taken by the multi-tumor marker protein chip detection system.Each group includes 10 samples.1.We adjusted the brightness of each image and chose the appropriate display mode of brightness.Using the function of auto measurement in the system,the results of 12 tumor markers were detected directly from each image.2.After choosing the appropriate brightness of each image,the points of 12 tumor markers in each image were analyzed,segmented.Then detect the results.The results of two groups were compared.Results: In the group of normal samples images,there is no statistically significant difference in the results of 12 tumor markers before or after image analysis,segmentation (P> 0.05);while in the group of tumor samples images,the results of 12 tumor markers that were analyzed and segmented are significantly different with that were not processed (P<0.05).Conclusions: In the detection of multi-tumor marker protein chip,image analysis and segmentation have no influence on the measurement of the image of normal samples.But there are more effects on the measurement of the image of tumor samples.Different display modes of brightness and different segmentation methods always lead to different results,even the opposite results.Therefore,before the final measurement in the detection of multi-tumor marker protein chip,it is necessary to choose the proper display modes of brightness and image analysis,image processing methods.
机译:目的:提高多肿瘤标志物蛋白芯片的准确性,为早期诊断提供更可靠的证据。方法:从多肿瘤拍摄的照片中随机选择两组正常样品图像和肿瘤样本图像标记蛋白芯片检测系统。组包括10个样本..我们调整了每个图像的亮度,并选择了适当的显示模式的亮度。在系统中自动测量的功能,直接检测到12个肿瘤标志物的结果选择每个图像的适当亮度后,分析每个图像中的12个肿瘤标记的点,分段。然后比较两组的结果。结果:在正常样本组中,在图像分析之前或之后的12个肿瘤标志物的结果没有统计学上显着差异,细分(P> 0.05);而在肿瘤样本的图像组中,结果为12 TU分析和分割的Mor标记与未加工的显着差异(P <0.05)。结论:在多肿瘤标志物蛋白芯片的检测中,图像分析和分割对正常样品的图像的测量没有影响但是,对肿瘤样本的图像的测量有更多的效果。亮度的显示模式和不同的分割方法总是导致不同的结果,即使是相反的结果。因此,在检测到多肿瘤标记的最终测量之前蛋白质芯片,有必要选择正确的亮度和图像分析模式,图像处理方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号