首页> 外文会议>International Workshop on Low Temperature Detectors >Characterization of SuperCDMS 1-inch Ge Detectors
【24h】

Characterization of SuperCDMS 1-inch Ge Detectors

机译:SuperCDMS 1寸GE检测器的表征

获取原文

摘要

The newly commissioned SuperCDMS Soudan experiment aims to search for WIMP dark matter with a sensitivity to cross sections of 5 x 10~(-45)cm~2 and larger (90% CL upper limit). This goal is facilitated by a new set of germanium detectors, 2.5 times more massive than the ones used in the CDMS-II experiment, and with a different athermal phonon sensor layout that eliminates radial degeneracy in position reconstruction of high radius events. We present characterization data on these detectors, as well as improved techniques for correcting position-dependent variations in pulse shape across the detector. These improvements provide surface-event discrimination sufficient for a reach of 5 x 10~(-45)cm~2.
机译:新委托SuperCDMS Soudan实验旨在搜索WIMP暗物质,敏感性为5×10〜(-45)cm〜2和更大的横截面(90%CL上限)。这一目标是由一组新的锗探测器促进的,比CDMS-II实验中使用的一组大量增加2.5倍,并且具有不同的动脉声子传感器布局,可消除高达半径事件的位置重建的径向退化。我们在这些探测器上呈现特征数据,以及改进用于校正探测器脉冲形状的位置依赖变化的技术。这些改进提供了足以达到5×10〜(-45)cm〜2的表面事件辨别。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号