首页> 外文会议>Annual Meeting of the Canadian Mineral Processors >A NON-NUCLEAR DENSITY METER AND MASS FLOW SYSTEM MEASURING MINING SLURRIES WITH ENTRAINED GAS
【24h】

A NON-NUCLEAR DENSITY METER AND MASS FLOW SYSTEM MEASURING MINING SLURRIES WITH ENTRAINED GAS

机译:具有夹带气体的非核密度计和质量流量系统测量矿泥浆

获取原文

摘要

The process control and cost of monitoring mining slurries is normally accomplished using a continuous mass flow system, conventionally embodying a volumetric magnetic flow meter and nuclear density meter. DuPont’s Maxville Mine at Starke, Florida, USA was chosen to examine costs associated with performance of a nuclear density meter. Since it is typical of many mid-sized establishments and has a long history in their use. The published accuracy under ideal conditions of a nuclear density meter is ± 1.0%, but in practice considerable ambiguity of cost in annual production implies ± 2% at best. Using such accuracy in a 400mm (16”) pipe carrying zircon slurry at 75,000 tons/day, the cost of ambiguity, together with initial and running costs, amount to nominally $962,000 per year.
机译:监测挖掘浆料的过程控制和成本通常使用连续的质量流量系统,通常体现体积磁流量计和核密度计。杜邦的Maxville Mine在佛罗里达州佛罗里达州,选择审查与核密度计的性能相关的成本。由于它是许多中型机构的典型,并且在使用中具有悠久的历史。核密度计的理想条件下发表的精度为±1.0%,但实际上,年生产成本的相当大的模糊性意味着±2%至关重要。在400毫米(16英寸)管中使用这种精度携带锆石浆料,在75,000吨/天,歧义的成本以及初始和运行成本,每年均为962,000美元。