【24h】

Benchmarking by Simulations

机译:通过模拟基准

获取原文

摘要

Energy efficiency of lift systems is of major concern due to the global demand for sustainable development. At present, there are international and national standards on energy efficiency of lift systems but the availability of one parameter that can master both motor drive efficiency and traffic control is limited. Thirteen years ago, the concept of with a unit J/kgm was proposed by the author. It was included in the Technical Guide of the Building Energy Code of Hong Kong SAR 2012 and 2015. However, due to technical and commercial difficulties, the number of systems with this parameter equipped is limited. It is therefore difficult to provide a solid figure of it for the purpose of benchmarking. In this article, significance and application of this parameter, method to monitor this parameter and results of different types of simulations, including different drive types, different traffic patterns, and different supervisory control methodologies, are reported. It can be shown that an acceptable system can achieve 50 J/kgm or below, a good system at around 40 J/kgm or below and an excellent system close to 30 J/kgm.
机译:由于全球对可持续发展需求,电梯系统的能源效率是主要的关注。目前,有国际和国家能源效率标准的升力系统,但一个参数的可用性可以掌握电机驱动效率和流量控制的限制。十三年前,提出了一个单位J / KG-M>的概念,提出了一个单位J / KGM。它包含在香港SAR 2012和2015年建筑能源守则的技术指南中。但是,由于技术和商业困难,配备此参数的系统数量有限。因此,难以为基准测试提供它的实心数字。在本文中,报告了对该参数的重要性和应用,监测该参数的方法和不同类型的模拟结果,包括不同的驱动类型,不同的流量模式和不同的监控方法。可以表明,可接受的系统可以实现50 j / kgm或更低,一个良好的系统,约为40 j / kgm或以下,并且优异的系统接近30 j / kgm。