The results from this present study show that chemical impurities are not responsible for the threshold dose effect. The threshold dose is an apparent effect, that is, an artifact of the spectroscopic measurement of multiple Fe(III)_(i):XO_(j) species formed at varying dose levels and it can be avoided by selecting an optimal wavelength that is sensitive to detecting only the species of interest. By resolving the threshold dose issue, it will be possible to precisely and accurately verify doses in 3D over a wide range of dose gradients produced by modern radiotherapy machines (i.e. IMRT).
机译:本研究结果表明,化学杂质不对阈值剂量效应负责。阈值剂量是一种表观效果,即,通过在不同剂量水平上形成的多种Fe(III)_(i)的光谱测量的伪像,并且可以通过选择最佳波长来避免它的XO_(j)种。对仅对兴趣物种进行敏感。通过解析阈值剂量问题,可以在通过现代放射疗法机器(即IMRT)生产的各种剂量梯度上精确准确地验证3D中的剂量。