IN-SITU (ON-SITE) GAS METER PROVING

机译:原位(现场)煤气表证明

获取原文
获取外文期刊封面目录资料

摘要

Natural gas flow rate measurement errors at field meter stations can result from the installation configuration, the calibration of the meter at conditions other than the actual operating conditions, or the degradation of meter performance over time. The best method for eliminating these or other sources of error is with in-situ (on-site) calibration of the meter. That is, the measurement accuracy of the field meter station should be verified under actual operating conditions by comparing to a "master" meter or "prover." Comparisons of flow meters in the field have been performed for nearly as long as flow meters have been in existence. For example, Figure 1 shows an orifice meter being compared to three 60-A tin meters (a.k.a., diaphragm meters) in Rosedale, Kansas in 1921. Each tin meter had the flow capacity of 1,800 standard cubic feet per hour. In this particular test, a 1.6% difference in reading was discovered between the orifice meter and the tin meters.
机译:现场仪表站的天然气流量测量误差可能是由于安装配置,仪表在实际操作条件以外的条件下校准,或随时间的仪表性能降低。消除这些或其他误差源的最佳方法是仪表的原位(现场)校准。也就是说,通过比较“主”仪表或“箴言”,应在实际操作条件下验证现场仪表站的测量精度。除了流量计已经存在,该领域中的流量计的比较已经存在。例如,图1示出了孔口表,其与1921年的Rosedale,堪萨斯州普罗斯莱斯的三个60-锡米(A.K.a.,Diamphragm Meters)进行了比较。每个锡表的流量为每小时1,800立方英尺。在这种特殊的测试中,在孔口计和锡米之间发现了1.6%的读数差异。