This paper presents a method to detect metallurgic short-circuits suitable for Optibar intercell bars in copper electrowinning and electrorefining processes. One of the primary achievements of this bar is to limit short-circuit currents to a maximum of 1.5 pu of the actual process current. However, low current short circuits are more difficult to detect. Thus, conventional short circuit detection instruments like gaussmeters and infrared cameras become ineffective. To overcome this problem the proposed method is based on detecting the voltage drop across anode-cathode pairs. The method does not affect the operation of the process and does not require modifications of the industrial plant. In order to verify the performance of this proposal experimental measurement done over a period of four months at a copper refinery are presented. A 100% success rate was obtained.
机译:本文介绍了一种用于检测适用于铜电氢化和电灌浆工艺中的光学性嵌段棒的冶金短路的方法。该栏的主要成果之一是将短路电流限制在实际过程电流的最大值为1.5 pu。但是,低电流短路更难以检测。因此,像高声计和红外相机那样的传统短路检测仪器变得无效。为了克服该问题,所提出的方法基于检测阳极阴极对的电压降。该方法不会影响过程的操作,并且不需要改进工厂。为了验证该提案的性能,在介绍铜炼油厂在四个月内完成的实验测量。获得了100%的成功率。