首页> 外文期刊>Industry Applications, IEEE Transactions on >Short-Circuit Detection for Electrolytic Processes Employing Optibar Intercell Bars
【24h】

Short-Circuit Detection for Electrolytic Processes Employing Optibar Intercell Bars

机译:采用Optibar Intercell棒的电解过程的短路检测

获取原文
获取原文并翻译 | 示例
       

摘要

This paper presents a method to detect metallurgical short circuits suitable for Optibar intercell bars in copper electrowinning and electrorefining processes. One of the primary achievements of this bar is to limit short-circuit currents to a maximum of 1.5 p.u. of the actual process current. However, low-current short circuits are more difficult to detect. Thus, conventional short-circuit detection instruments like gaussmeters and infrared cameras become ineffective. To overcome this problem, the proposed method is based on detecting the voltage drop across anode-cathode pairs. The method does not affect the operation of the process and does not require modifications of the industrial plant. In order to verify the performance of this proposal, experimental measurements done over a period of four months at a copper refinery are presented. A 100% success rate was obtained.
机译:本文提出了一种在铜电解精炼和电精炼过程中检测适用于Optibar晶胞间棒的冶金短路的方法。该条的主要成就之一是将短路电流限制为最大1.5p.u。实际过程电流。但是,低电流短路更难检测。因此,诸如高斯计和红外相机的常规短路检测仪器变得无效。为了克服这个问题,提出的方法基于检测阳极-阴极对之间的电压降。该方法不影响过程的操作,并且不需要修改工业工厂。为了验证该建议的性能,提出了在铜精炼厂进行的为期四个月的实验测量。获得了100%的成功率。