CORROSION RESISTANCE OF GALVANIZED BARS IN CONCRETE STRUCTURES EXPOSED IN THE CARIBBEAN

机译:加勒比地区混凝土结构中镀锌棒的耐腐蚀性

获取原文

摘要

The aim of this research is to assess the corrosion performance of galvanized reinforcing bars in concrete elements exposed to natural tropical marine environment in the Mexican Caribbean, using limestone aggregates and ordinary Portland cement (OPC). Reinforced prisms of concrete with water to cement (w/c) ratios of 0.4, 0.5, 0.6 and 0.7 were half-immersed in seawater at a seashore site in the Yucatan Peninsula (Sisal). Corrosion was monitored by corrosion potential and linear polarization resistance measurements. The chloride penetration in the concrete was also measured. Corrosion data showed that, after 693 days of exposure, the corrosion current density values of the zinccoated bars were, 0.1, 0.08, 0.14; and 0.19 mu A/cm~2, in (w/c) ratios of 0.4, 0.5, 0.6 and 0.7, respectively. The corresponding current densities for black steel were, 0.09, 0.18, 0.32, and 0.52 mu A/cm~2. These corrosion current densities correspond to a zinc coating thickness loss of 1.2 mu m/y to 2.85 mu m/y. The corrosion rate of black steel was between 1 mu m/y and 6 mu m/y.
机译:该研究的目的是评估墨西哥加勒比地区暴露于天然热带海洋环境的混凝土元件中镀锌加强杆的腐蚀性,采用石灰石骨料和普通波特兰水泥(OPC)。用水到水泥(W / C)的加强棱镜为0.4,0.5,0.6和0.7的水泥,在尤卡坦半岛(Sisal)的海滨部位浸入海水中。通过腐蚀电位和线性偏振电阻测量监测腐蚀。还测量了混凝土中的氯化物渗透。腐蚀数据表明,在暴露693天后,Zinccoated棒的腐蚀电流密度值为0.1,0.08,0.14;和0.19μA/ cm〜2,(w / c)比分别为0.4,0.5,0.6和0.7。黑钢的相应电流密度为0.09,0.18,0.32和0.52μA/ cm〜2。这些腐蚀电流密度对应于1.2μm/ y至2.85μm/ y的锌涂层厚度损失。黑钢的腐蚀速率在1μm/ y和6μm/ y之间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号