In order to improve the durability and cost performance of superheater in high efficiency WTE boiler, new Ni base alloy/YSZ dual coating systems using plasma-jet spray technology has been developed, and then the life of these coatings sprayed on 500 deg C/9.8MPa high-efficiency WTE boiler superheater was evaluated by the long term field corrosion test. Three kinds of coating layer of alloy 625/YSZ, NiCrSiB alloy/YSZ and Cr_3C_2 centre dot NiCr sprayed by 100kW plasma-jet system both on site and on shop were installed in tertialy and secondary superheater having high metal temperature of 450 - 500 deg C, and exposed for more than 1.3 years. As the results of the field corrosion test, alloy 625/YSZ and NiCrSiB alloy/YSZ coatings with inorganic sealant showed excellent durability more than 1.5 years compaired with conventional NiCrSiB alloy HVOF system in tertialy superheater. Based on the detail investigation of cut-off tube samples, A durability of each coatings reduce with increase in corrosivity of combustion gas. YSZ and inorganic sealant were clarified to work as a penetration barrier for corrosive components in deposits to coating/base metal interface. Especially, in soot blower affected position, Cr_3C_2 centre dot NiCr layer sprayed in secondary superheater peeled off by thermal cyclic factor after four months exposure, while large corrosion prevention effect was observed in Ni base alloy/YSZ layer regardless of partial peeling-off of YSZ layer. An application of Ni base alloy/YSZ coatings for actual boiler is expected in the future.
机译:为了提高高效WTE锅炉过热器的耐用性和成本性能,开发了新的Ni基合金/ YSZ双涂层系统,采用等离子喷射喷雾技术,然后在500°C / 9.8上喷涂这些涂层的寿命MPA高效率WTE锅炉过热器通过长期腐蚀试验评估。在现场和商店内喷涂100kW等离子体喷射系统的Nicrsib合金/ YSZ和CR_3C_2中央点NiCr的三种涂层均采用100kW等离子体喷射系统。高金属温度为450 - 500°C的高级过滤器,并暴露超过1.3岁。由于现场腐蚀试验的结果,具有无机密封剂的合金625 / YSZ和Nicrsib合金/ YSZ涂层显示出优异的耐久性,在特定过热器中使用常规的Nicrsib合金HVOF系统进行了优异的1.5年。基于切断管样品的细节调查,随着燃烧气体腐蚀性的增加,每种涂层的耐久性降低。澄清了YSZ和无机密封胶作为涂层/贱金属界面的沉积物中的腐蚀组分的渗透屏障。特别是在烟气鼓风机受影响的位置,CR_3C_2中央点NiCR层喷涂在四个月暴露后通过热循环因子剥离的二次过滤器,而在Ni基合金/ YSZ层中观察到大的腐蚀效果,无论YSZ的部分剥离如何层。预计将来将来对实际锅炉进行Ni基合金/ YSZ涂层的应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号