首页> 外文会议>European Junior Scientists Workshops >Model connectors for integrated simulations of urban wastewater systems
【24h】

Model connectors for integrated simulations of urban wastewater systems

机译:用于城市污水系统集成模拟的模型连接器

获取原文

摘要

In order to perform simulations of the integrated wastewater system, state variables of sub-system models (sewer, activated sludge, river) must be translated from one model to the other. A connector between ASM1 (Henze et al. 2000) and RWQM1 (Shanahan et al. 2001) is described in this paper to introduce the general approach developed to overcome this necessity. Inherent features of this connector are its closed elemental mass balances. The COD fractions of ASM1 have been split over the COD fractions of RWQM1, while balance terms were used to close elemental balances. Also the different environmental conditions in the systems (activated sludge, sewer and river) have been taken into account. An evaluation of the influence of several connector and model parameters on connector balance terms and outputs has been performed. Some results of a case study concerning the river Lambro (Italy) are described to show an application of such model connection approach.
机译:为了执行综合废水系统的模拟,必须从一个模型转换为另一个模型的子系统模型(下水道,激活污泥,河流)的状态变量。本文描述了ASM1(Henze等人,2000)和RWQM1(Shanahan等,2001)之间的连接器,以介绍为克服这种必要性而开发的一般方法。该连接器的固有功能是其封闭的元素质量余额。 ASM1的COD部分已分开RWQM1的COD分数,而平衡术语用于关闭元素余额。还考虑了系统(活性污泥,下水道和河流)的不同环境条件。已经进行了对连接器平衡术语和输出上的若干连接器和模型参数的影响的评估。描述了关于河流河(意大利)的案例研究结果,以显示这种模型连接方法的应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号