首页> 外文会议>International Conference on Environmental Systems >Experimental study on periodical fluctuations of the diffuse vapor/gas front during operation of a gas-loaded heat pipe
【24h】

Experimental study on periodical fluctuations of the diffuse vapor/gas front during operation of a gas-loaded heat pipe

机译:气负载热管期间漫反应蒸汽/气体前部的期周期波动的实验研究

获取原文

摘要

A test sequence with two gas-loaded heat pipes of different geometry with external noncondensable gas reservoirs was performed in order to detect, analyze and classify conjugated and detached fluctuations of evaporator temperature, operating temperature and the position of the vapor/gas front after start-up. The fluctuations become noticeable at operation with more than half of the condenser open and gain force the more the front approaches the condenser end. It was found that amplitude, frequency and polarity of the fluctuations also depend on the magnitude of a heat load step change, the gas charge and the working fluid. A method is mentioned of how to dampen the fluctuations.
机译:进行具有外部不可缩续的气体储层的不同几何形状的两个气体加热管的试验序列,以检测,分析和分类蒸发器温度,工作温度和蒸汽/气体前方位置的叠加和分离的波动 - 向上。波动在运行中变得明显,在开口的一半以上的冷凝器打开并获得力的前部接近冷凝器端。发现波动的幅度,频率和极性也取决于热负荷步骤变化,气体电荷和工作流体的大小。提到了如何抑制波动的方法。