Sacrificial anode cathodic protection was applied to the steel pipe piles of refined product jetty of CSPC Nanhai Petrochemical Project, the largest cooperant petrochemical project in domestic. This article includes project general situation, technical targets of cathodic protection, sacrificial anode cathodic protection calculations, electrical connection of the steel pipe piles, underwater welding installation of sacrificial anode, protection effectiveness measurement. According to the project specification, the protection rule and the design parameter of this project are different from the similar internal project, the project specification requires the protection potential should be controlled between –0.85V and –1.15V(vs. Cu/CuSO4 reference electrode). 60mA/m 2 is selected as the protection current density of the coated steel pipe pile in seawater. The installation of sacrificial anode adopts advance underwater local CO2 drainage half-auto welding procedure. By general underwater visual inspection, underwater video selective examination, protection potential measurement of the steel pipe piles, every target are satisfied with the requirement of the project specification, the quality of this project is excellent.
机译:牺牲阳极阴极保护应用于CSPC南海石化工程精制产品码材的钢管桩,是国内最大的合作石化项目。本文包括项目一般情况,阴极保护技术目标,牺牲阳极阴极保护计算,钢管桩电连接,牺牲阳极水下焊接安装,保护效果测量。根据项目规范,该项目的保护规则和设计参数与类似的内部项目不同,项目规范要求保护电位应在-0.85V和-1.15V之间控制(VS。CU / CUSO4参考电极。 )。选择60mA / m 2作为海水中涂层钢管桩的保护电流密度。牺牲阳极的安装采用先进水下局部CO2排水半自动焊接程序。通过一般的水下目视检查,水下视频选择性检查,保护潜力测量钢管桩,每个目标都满足了项目规范的要求,这个项目的质量很好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号