首页> 外文会议>European Symposium on Computer Aided Process Engineering >Comparison between Different Control Approaches of the UOP Fluid Catalytic Cracking Unit
【24h】

Comparison between Different Control Approaches of the UOP Fluid Catalytic Cracking Unit

机译:UOP流体催化裂化单元不同控制方法的比较

获取原文

摘要

Different traditional and advanced control strategies have been tested and the performance investigated, revealing their incentives. The investigated control approaches are: conventional decentralized PID control, MPC control based on analytical model, MPC based on Artificial Neural Networks (ANN) model and Fuzzy Logic Control (FLC). Comparative control results are shown for the multivariable control structures, aimed to control the main variables of the unit, such as: reactor and regenerator temperature, catalyst inventory in the reactor and oxygen content in the regenerator stack gas, in the presence of typical disturbances. The results reveal the incentives of the investigated approaches (with analytical or ANN models) over the classical decentralized PID control scheme but also the benefits of the Fuzzy Logic Control.
机译:已经测试了不同的传统和先进的控制策略,并调查了表现,揭示了他们的激励措施。调查的控制方法是:常规分散的PID控制,基于分析模型的MPC控制,基于人工神经网络(ANN)模型和模糊逻辑控制(FLC)。对比较控制结果显示为多变量控制结构,旨在控制单位的主要变量,例如:反应器和再生器温度,反应器中的催化剂库存和再生器堆气体中的氧含量,在典型的干扰存在下。结果揭示了在经典分散的PID控制方案上进行了调查方法(用分析或ANN模型)的激励,但也是模糊逻辑控制的益处。