At revision of EN 14179-1 describing the Heat Soak Test (HST) for Thermally Toughened Building Glass, a holding temperature decrease from 290°C to 260°C and a limitation of the heating-up ramp speed to three degrees Celsius per minute are comprised. Temperature decrease was necessary because previous R&D had shown a principal incompleteness of the NiS a to β transformation at too high temperature. On the other hand, a discussion on the holding time started because, following Arrhenius' law, temperature decrease should be compensated by longer time. At this occasion, in order to help to clarify the situation, we publish new data from seldom breakages on buildings, collected over the past 30 years, and compare the results with a dataset from breakages in Heat Soak Test.
机译:在EN 14179-1的热浸渍试验(HST)的热浸渍试验(HST),保持温度从290°C减小到260°C,并将加热坡度的限制为每分钟三摄氏度包括。温度降低是必要的,因为先前的研发显示了NIS A对β转化的主要不完全性在过高的温度下。另一方面,在Arrhenius的定律之后,对持有时间开始的讨论,应通过更长的时间来补偿温度下降。在此场合,为了帮助澄清这种情况,我们在过去30年中收集的建筑物中很少出版的新数据,并将数据集与热量浸泡测试中的破损进行比较。