CHF correlation against inlet subcoolings was given in non-dimensional form based on the experimental data performed in Part 1 of this paper. The correlation can describe not only the CHFs obtained in this work at the inlet pressure of 800 kPa but also the authors' published CHFs data (1284 points) for the wide range of P{sub}(in)=159 kPa to 1 MPa, d=3 to 12 mm, L=33 to 149 mm, ΔT{sub}(sub,in)=10 to 151 K and u=4.0 to 13.3 m/s within ±15 % difference for 50 K≤ΔT{sub}(sub,in)≤151 K.
机译:基于本文第1部分中的实验数据,以非尺寸形式给出了对进样口过冷的CHF相关性。不仅可以描述在800 kPa的入口压力下在这项工作中获得的CHF而且作者公布的CHFS数据(1284点),用于广泛的P {sub}(in)= 159kpa至1 mpa, d = 3至12 mm,L = 33至149mm,Δt{sub}(sub)= 10至151k,u = 4.0至13.3m / s在±15%差的±15%以内为50k≤Δt{sub} (亚,in)≤151k。