High temporal resolution of CO{sub}2 and H{sub}2O measurement were made in a combusting field to realize an in-situ combustion diagnostics based on diode laser absorption sensors. HITRAN 98 and HITEMP database of high temperature CO{sub}2 and H{sub}2O were used to select their detection. 4878.193 cm{sup}(-1), 5008.101 cm{sup}(-1) and R(50) lines were selected to define H{sub}2O temperature and CO{sub}2 concentration. As a result, measured H{sub}2O temperature agreed with measurement with R-type thermocouple within standard deviation. CO{sub}2 concentration, however, showed large value than we expected.
机译:在燃烧场中进行CO {SUB} 2和H {SUB} 2O测量的高时间分辨率,以实现基于二极管激光吸收传感器的原位燃烧诊断。 HITRAN 98和HITEMP数据库的高温CO {SUB} 2和H {SUB} 2O用于选择其检测。选择4878.193cm {sup}( - 1),5008.101cm {sup}( - 1)和r(50)行以定义h {sub} 2o温度和co {sub} 2浓度。结果,测量的H {Sub} 2O温度同意在标准偏差内使用R型热电偶测量。然而,CO {sub} 2浓度显示出比我们预期的大值。