Application of TIVA in design debug

机译:Tiva在设计调试中的应用

获取原文

摘要

Thermally-Induced Voltage Alteration (TIVA) is a relatively new technique for locating electrical defects in integrated circuits [1,2]. This paper describes a novel application of TIVA, to locate design anomalies. A newly designed integrated circuit with high and inconsistent Quiescent Power Supply Current (IDDQ) was initially diagnosed with limited success using various failsite isolation techniques. The TIVA technique was successful in accurately locating design anomalies. Results from TIVA identified a spurious ring oscillator in the design. Design modifications carried out using a focussed ion beam (FIB), verified the accuracy of the results from TIVA. This study clearly extends the use of TIVA beyond that of locating electrical defects and anomalies into the realm of design debugging.
机译:热诱导的电压改变(TIVA)是用于定位集成电路中的电缺陷的相对较新的技术[1,2]。本文介绍了一种新颖的TIVA应用,以定位设计异常。具有高和不一致的静态电源电流(IDDQ)的新设计的集成电路最初诊断出使用各种故障分离技术的有限成功。 TIVA技术在准确定位设计异常方面是成功的。 Tiva的结果确定了设计中的虚假环形振荡器。使用聚焦离子束(FIB)进行的设计修改,验证了TIVA结果的准确性。本研究显然扩展了利用以超出将电气缺陷和异常定位到设计调试领域的使用。