【24h】

Application of TIVA in Design Debug

机译:TIVA在设计调试中的应用

获取原文
获取原文并翻译 | 示例

摘要

Thermally-Induced Voltage Alteration (TIVA) is a relatively new technique for locating electrical defects in integrated circuits. This paper describes a novel application of TIVA, to locate design anomalies. A newly designed integrated circuit with high and inconsistent Quiescent Power Supply Current (IDDQ) was initially diagnosed with limited success using various failsite isolation techniques. The TIVA technique was successful in accurately locating design anomalies. Results from TIVA identified a spurious ring oscillator in the design. Design modifications carried out using a focussed ion beam (FIB), verified the accuracy of the results from TIVA. This study clearly extends the use of TIVA beyond that of locating electrical defects and anomalies into the realm of design debugging.
机译:热感应电压变化(TIVA)是一种用于定位集成电路中电缺陷的相对较新的技术。本文介绍了TIVA在定位设计异常中的一种新颖应用。最初使用各种故障隔离技术诊断出一种新设计的具有高且不一致的静态电源电流(IDDQ)的集成电路,但成功率有限。 TIVA技术成功地准确定位了设计异常。 TIVA的结果确定了设计中的伪环形振荡器。使用聚焦离子束(FIB)进行的设计修改,验证了TIVA结果的准确性。这项研究清楚地将TIVA的使用范围扩大到了排除电气缺陷和异常的位置之外,从而进入了设计调试领域。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号