RHIC Beam Loss Monitor System Commissioning in RHIC Year 0 Run

机译:RHIC束损失监控系统调试RAC年0运行

获取原文

摘要

The RHIC Loss Monitor System (BLM) was successfully commissioned during the RHIC (Relativistic Heavy Ion Collider) Year 0 Run (summer of 1999). The system consists of 363 argon ionization detectors distributed around the ring. The signals are digitized in a distributed multiplexed ADC system and displayed at a 1 Hz rate in the control room. During the commissioning, the beam loss monitor system was extensively used for first turn beam steering. An impressive example of the capabilities of this system was the ability to locate a thin obstruction to within one magnet length, even through this obstruction transmitted most of the beam. With this information we were able to achieve circulating beam. This paper will discuss the RHIC beam loss monitor system design and testing. The data acquired during the RHIC commissioning run with also be presented.
机译:在RHIC(相对论重型离子撞机)年0次运行(1999年夏季)成功委托了RAM损失监测系统(BLM)。该系统由分布在环周围的363个氩电离探测器组成。信号在分布式多路复用ADC系统中数字化,并在控制室中以1 Hz速率显示。在调试期间,光束损耗监控系统广泛用于第一转向梁转向。这种系统能力的令人印象深刻的示例是能够在一个磁体长度内定位薄障碍物,即使通过该障碍物传输大部分梁。通过这些信息,我们能够实现循环梁。本文将讨论RAIR梁损耗监控系统设计和测试。在RHIC调试期间获得的数据也在呈现。