Spontaneous anti-Stokes Raman scattering from N_2 was employed to measure the temperature profiles inside an industrial furnace with a water-cooled probe. Prior to the field measurements, the system performance was evaluated and maximized in a laboratory furnace at several temperatures below 1300·K. The temperatures of about 1500K have been measured in the industrial furnace, and they are in agreement with data recorded with a thermocouple probe. Spontaneous anti-Stokes Raman was found to be a reliable tool for non-intrusive absolute temperature measurements in industrial furnaces with relatively clean gas streams. Little dependence was found on the laser power and optics mis-alignment.
机译:采用来自N_2的自发性反斯托克斯拉曼散射,以测量工业炉内的温度型材,用水冷却探针。在现场测量之前,在低于1300·k的几个温度下在实验室炉中评估并最大化系统性能。在工业炉中测量了约1500K的温度,并与用热电偶探头记录的数据一致。发现自发的防斯托克斯拉曼是一种可靠的工具,用于工业炉中的非侵入式绝对温度测量,具有相对清洁的气流。在激光功率和光学误导上发现了很少的依赖。