首页> 外文会议>International Symposium for Testing and Failure Analysis >Case Study Failure Analysis of an Ultra-High Vacuum Enclosure Made of a Silicon Chip and Borosilicate Glass for the Cold Atom Laboratory
【24h】

Case Study Failure Analysis of an Ultra-High Vacuum Enclosure Made of a Silicon Chip and Borosilicate Glass for the Cold Atom Laboratory

机译:用于冷原子实验室的硅芯片和硼硅晶玻璃制成的超高真空外壳的案例研究失效分析

获取原文

摘要

In this paper, a failure analysis case study on a custom-built vacuum enclosure is presented. The enclosure's unique construction and project requirement to preserve the maximum number of units for potential future use in space necessitated a fluorocarbon liquid bath for fault isolation and meticulous sample preparation to preserve the failure mechanism during failure analysis.
机译:本文介绍了定制真空外壳的故障分析案例研究。外壳的独特施工和项目要求保留最大单位数,以便在空间中使用潜在的未来使用,需要用于故障隔离和细致的样品制备的氟碳液浴,以保持失效分析期间的失效机制。