Here we propose a high scan rate leak test method which was developed based on the test procedure described in the IES standard. This method has been proposed to the new international standard, ISO/TC 209. The scanning rate of the probe, Sr [cm/s] is subject to the number of Np, which is the expected number of particle counts which characterize the designated leak. This proposal made it clear that the most optimum scanning will be achieved by confirming the observed counts, C=0, with the scan rate of Sr decided by the assumption of Np=4 or 3.
机译:在这里,我们提出了一种高扫描速率泄漏测试方法,该方法是基于IES标准中描述的测试程序开发的。该方法已经提出了新的国际标准ISO / TC 209.探头的扫描速率,SR [CM / S]受到NP的数量,这是表征指定泄漏的预期粒子计数的数量。该提议明确表示,通过确认观察到的计数C = 0,C = 0的最佳扫描将通过SR的扫描速率通过NP = 4或3来决定。