Air cooled loop thermosyphon cooling system for high heat load CPUs: design and performance simulation

机译:空气冷却环热旋流式冷却系统,用于高热负载CPU:设计和性能模拟

获取原文

摘要

A new innovative partially passive cooling system was conceived and designed for cooling future generation CPUs of 2U servers operating in datacenter racks with a heat load target of 600W. The cooling includes passive flow of a two-phase working fluid inside of a closed loop thermosyphon (LTS), comprised of an evaporator, a condenser, and the connections between them (a riser and a downcomer). The buoyance in the riser is the driver of the flow in the loop, which increases when the heat load dissipated from the CPU is increased (self-controlled system). The newly designed LTS is entirely in aluminum, meaning it is cost effective and light in weigh. Two units can be installed side-by-side in standard 2U server racks to handle both CPUs. The new design (patent pending [1]) is characterized by a new concept of a duo-thermosyphon with headers, riser and downcomer that maximize the thermal-hydraulic performance of the entire loop and frontal face for airflow. The cooling system is partially passive since the heat transported by the LTS is removed via forced air convection, i.e. a fan. Using louvered fin coil technology adapted from automotive applications for the condenser, the energy consumption of the fan can be significantly reduced compared to conventional cold plates, if one so wishes. The total height of the LTS unit is 66mm and its footprint handles large size CPUs without any need of an oversized heat spreader. Simulations with JJ Cooling Innovation’s inhouse code considering different environmentally friendly working fluids, air volumetric flow rates and heat loads were performed and are shown to demonstrate the potential of the proposed LTS cooling system.
机译:构思了一种新的创新部分被动冷却系统,并设计用于冷却在数据中心机架中运行的2U服务器的未来发电CPU,其热负荷目标为600W。冷却包括由蒸发器,冷凝器和它们之间的连接(提升管和降液管)的闭环热烃(LTS)内部的双相工作流体的被动流动。提升管中的浮雕是环中流动的驱动器,当从CPU散发的热负荷增加(自控系统)时增加。新设计的LTS完全是铝制,这意味着它具有成本效益和重量的重量。两个单位可以在标准的2U服务器机架中并排安装,以处理两个CPU。新设计(专利申请[1])的特点是具有带头部,立管和降液管的Duo-Thermosyphon的新概念,最大化整个环路的热液压性能和用于气流的前面。冷却系统是部分被动的,因为通过强制空气对流输送的LTS传输的热量,即风扇。使用从汽车应用适用于电容器的百叶窗鳍线圈技术,与传统的冷板相比,风扇的能量消耗可以显着减少,如果如此希望。 LTS单元的总高度为66毫米,其脚印处理大尺寸的CPU,无需任何超大的散热器。考虑不同环保的工作流体的JJ冷却创新的Inhouse代码进行了模拟,并进行了空气体积流量和热载荷,并显示出所提出的LTS冷却系统的电位。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号