首页> 外文会议>Conference on high heat flux engineering >Thermo-mechanical failure criteria for x-ray windows and filters and comparison with experiments
【24h】

Thermo-mechanical failure criteria for x-ray windows and filters and comparison with experiments

机译:X射线窗口和过滤器的热机械故障标准以及实验比较

获取原文

摘要

Synchrotron x-ray windows are vacuum separators and are usually made of thin beryllium metal. Filters are provided upstream of the window to filter out the soft x-rays to protect the window from overheating and failing. The filters are made of thin carbon products or sometimes beryllium, the same material as the window. Because the window is a vacuum separator, understanding its potential structural failure under thermal load is very important. Current structural failure models for the brazed windows and filters under thermal stresses are not very accurate. Existing models have been carefully examined and found to be inconsistent with the actual failure modes of windows tested. Due to the thinness of the filter/window, the most likely failure mode is thermal buckling. In fact, recent synchrotron tests conducted in Japan on window failures bear out this position. In this paper, failure criteria for filters/windows are proposed, and analyses are performed and compared with the experimental results from various sources. A consistent result is found between the analysis and reported experiments.
机译:Synchrotron X射线窗户是真空分离器,通常由薄铍金属制成。过滤器设置在窗口的上游,以滤除软X射线以保护窗口过热和失败。过滤器由薄碳产品或有时铍,与窗口相同的材料制成。因为窗户是真空分离器,所以在热负荷下理解其潜在的结构故障非常重要。热应力下钎焊窗口和过滤器的电流结构故障模型不是很准确。已仔细检查现有模型,并发现与测试的实际故障模式不一致。由于过滤器/窗口的薄,最可能的故障模式是热屈曲。事实上,在窗口失败的日本进行了最近在日本进行的同步测试突出了这个位置。在本文中,提出了用于过滤器/窗口的故障标准,并进行分析并与各种来源的实验结果进行比较。在分析和报告的实验之间发现了一致的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号