首页> 美国政府科技报告 >Thermo-mechanical failure criteria for x-ray windows and filters and comparison with experiments
【24h】

Thermo-mechanical failure criteria for x-ray windows and filters and comparison with experiments

机译:X射线窗口和过滤器的热机械失效标准以及与实验的比较

获取原文

摘要

Synchrotron x-ray windows are vacuum separators and are usually made of thin beryllium metal. Filters are provided upstream of the window to filter out the soft x-rays to protect the window from overheating and failing. The filters are made of thin carbon products or sometimes beryllium, the same material as the window. Because the window is a vacuum separator, understanding its potential structural failure under thermal load is very important. Current structural failure models for the brazed windows and filters under thermal stresses are not very accurate. Existing models have been carefully examined and found to be inconsistent with the actual failure modes of windows tested. Due to the thinness of the filter/window, the most likely failure mode is thermal buckling. In fact, recent synchrotron tests conducted in Japan on window failures bear out this position. In this paper, failure criteria for filters/windows are proposed, and analyses are performed and compared with the experimental results from various sources. A consistent result is found between the analysis and reported experiments. A series of additional analyses based on the proposed failure criteria is also carried out for filter and window designs for the third generation synchrotron beamline front ends. Comparative results are presented here.