首页> 外文会议>IEEE Sensors Conference >Miniaturized photonic crystal fiber tip sensor for refractive index sensing
【24h】

Miniaturized photonic crystal fiber tip sensor for refractive index sensing

机译:用于折射率传感的小型化光子晶体纤维尖端传感器

获取原文

摘要

We report on the fabrication of a miniaturized photonic crystal fiber (PCF) tip sensor for sensitive liquid refractive index measurement. The PCF tip sensor has a hybrid configuration of Fabry-Perot (FP) and modal interferometer. A short length (less than 1 mm) of PCF is spliced to a standard single mode fiber. An air bubble is created in the splice region forming the FP cavity. The air holes are fully collapsed on both sides of the PCF. The collapsed sections act as multimode fibers which excite and recombine higher order modes experiencing optical path difference (OPD) than that of the core mode and forming modal interference. The end of the PCF is modified to a solid sphere by fusion arc splicer. Experimental results show that the sensitivity of the probe can reach up to 21.4 nm/RIU (refractive index unit) to detect bulk liquid with refractive indices from 1.33 to 1.4.
机译:我们报告了用于敏感液体折射率测量的小型光子晶体纤维(PCF)尖端传感器的制造。 PCF尖端传感器具有Fabry-Perot(FP)和模态干涉仪的混合配置。短长度(小于1 mm)的PCF拼接到标准的单模光纤。在形成FP腔的拼接区域中产生气泡。气孔完全折叠在PCF的两侧。折叠部分充当多模纤维,其激发和重组经历光程差(OPD)的高阶模式比核心模式和形成模态干扰。通过Fusion Acc Splicer将PCF的末端修改为固体球。实验结果表明,探针的敏感性可达高达21.4nm / RiU(折射率单元),以检测折射率为1.33至1.4的折射率。