Regarding shielding effectiveness measurements in mode-stirredchambers there are a lot of unknown variables concerning the operationmode of the chamber and the evaluation of measurement data. This paperis aimed at determining the best operation mode-e.g. mode-tuned ormode-stirred mode-and the minimum number of measurement samples. Theresults obtained from shielding effectiveness measurements are comparedto measurements carried out in an anechoic chamber. It is shown thatboth measurement environments are comparable for the average shieldingeffectiveness of an equipment under test (EUT)
机译:关于在模式搅拌下的屏蔽效能测量 暗室中有许多与操作有关的未知变量 腔室模式和测量数据评估。这篇报告 旨在确定最佳操作模式-例如模式调整或 模式-搅拌模式-以及最少的测量样本数。这 比较从屏蔽效能测量获得的结果 在消声室中进行的测量。结果表明 两种测量环境的平均屏蔽性能均相当 被测设备(EUT)的有效性