The authors have developed a fuzzy control system to provideclosed-loop control of mean arterial pressure (MAP) in postsurgicalpatients in a cardiac surgical intensive care unit setting, byregulating sodium nitroprusside infusion. The core of the controlalgorithms is a nonlinear proportional-integral (PI) controller, whichprecisely represents the simplest fuzzy controller. Theproportional-gain and integral-gain are adjusted continuously accordingto the error and rate change of the error of MAP. Twelve postoperativepatients who exhibited elevated MAP following coronary artery bypassgrafting procedures took part in the study. The length of time thattwelve patients were on the fuzzy control system ranged from 1 h 45 minto 18 h 7 min. The total fuzzy-controller run time was 95 h 13 min.Clinical results showed that the average percentage of time in which MAPstayed between 90% and 110% of the MAP setpoint was 89.31%, with astandard deviation of 4.96%
机译:作者已经开发出一种模糊控制系统,以提供 术后平均动脉压(MAP)的闭环控制 心脏外科重症监护病房设置的患者 调节硝普钠的输液。控制的核心 算法是非线性比例积分(PI)控制器, 精确地代表了最简单的模糊控制器。这 比例增益和积分增益根据 MAP的误差和速率变化。十二个术后 冠状动脉搭桥术后MAP升高的患者 嫁接程序参与了研究。的时间长度 在1小时45分钟的范围内,有12名患者处于模糊控制系统上 至18小时7分钟模糊控制器的总运行时间为95小时13分钟。 临床结果表明,其中MAP的平均时间百分比 保持在MAP设定值的90%至110%之间,为89.31%, 标准偏差4.96%