摘要

This article presents an evaluation of a prototype optical tracking system intended for use in computer-assisted orthopedic surgery. The device is based on a smartphone with a built-in video camera, and an external miniature time-of-flight camera. It is able to automatically recognize a surgical instrument based on its shape and appearance, and to determine its orientation relative to an array of light-reflective markers. The experiments were done in a measurement configuration and with the instruments that are specific to computer-assisted implantation of the acetabular component in total hip replacement surgery. The evaluation included the recognition rate of the instruments, and the angular accuracy of the system. The results show, that the accuracy is comparable to that obtained by conventional tracking devices in clinical settings, and partially meets the requirements specified in the literature for hip surgery.
机译:本文介绍了旨在用于计算机辅助骨科手术的原型光学跟踪系统的评估。该设备基于带有内置摄像头和外部微型飞行时间摄像头的智能手机。它能够根据其形状和外观自动识别手术器械,并确定其相对于反光标记阵列的方向。实验是在测量配置下进行的,并且使用了在全髋关节置换手术中专用于计算机辅助髋臼组件植入的仪器。评估包括仪器的识别率和系统的角度精度。结果表明,该准确性与临床环境中传统跟踪设备所获得的准确性相当,并且部分满足了髋关节外科手术文献中指定的要求。